PROJECT NAME |
PROJECT DESCRIPTION |
OWNER |
Dixie Water Association
Hydraulic Analysis
|
Hydraulic analysis of the Dixie Water Association system to model the existing
domestic water flows.
|
Dixie Water Association
|
City of Petal
Hydraulic Analysis
|
Hydraulic analysis of the City of Petal water system including domestic water
flows, fire flows, and water quality analysis.
|
City of Petal
|
Glendale Utility District
Highway 42 Water Relocations |
Relocation of the water and sewer lines along 3 miles of the new alignment of
Highway 42 in Glendale just north of Hattiesburg, Mississippi.
 |
Glendale Utility District
Hattiesburg, MS |
North Lamar Water Association
New 500,000 gal. Water Tank |
Design of the tank including hydraulically analyzing the effects
of the new tank on the existing North Lamar water system, and
inspection of the construction.
 |
North Lamar Water Association 4906 Old Hwy 11 - #8
Hattiesburg, MS 39402 |
City of Collins
300,000 Gallon Elevated Tank |
Design and Inspection |
City of Collins
P. O. Box 400
Collins, MS 39428
601-765-4492 |
Hattiesburg Industrial Park
Elevated Tank, Water & Sewer Systems |
Design and Inspection |
City of Hattiesburg P.O. Box 1898
Hattiesburg, MS 39403
601-545-4640 |
North Lamar Water Association
4 Wells, 2 Elevated Tanks and Water & Sewer Systems |
Design and Inspection |
North Lamar Water Association 4906 Old Hwy 11 - #8
Hattiesburg, MS 39402 |
Dixie Community Utility Assoc.
3 Wells, 3 Elevated Tanks and Water Distribution System |
Design and Inspection |
Dixie Community Utility Association
930 Bonhomie Road
Hattiesburg, MS 39401
601-582-5038 |
Barrontown Utility Association
3 Wells, 3 Elevated Tanks and Water Distribution System |
Design and Inspection |
Barrontown Utility Association
101 Dogwood Lane
Petal, MS 39465
601-544-3535 |
Runnelstown Utility District
2 Wells, 2 Tanks and Water Distribution System |
Design and Inspection |
Runnelstown Utility District
39 Corinth Church Road
Petal, MS 39465
601-582-9873 |
City of Collins Water
Improvements to include hydraulic analysis, elevated tank,
domestic flows, and line sizing along with fire flows and line
sizing.  |
Performance and evaluation of hydraulic analysis and pressures
of line sizes. To evaluate quality of flows throughout the system.
Coordination with the Mississippi State Department of Health
to insure Minimum Design Standards were met. Address existing
supply and potential for expansion. Hydraulic Analysis, additionally,
addressed fire demand in accordance with Mississippi State Rating
Bureau. A cost analysis was performed of all options. |
City of Collins
P. O. Box 400
Collins, MS 39428
601-765-4492 |
City of Lumberton Water Improvements to include hydraulic analysis,
elevated tank, domestic flows, and line sizing along with fire
flows and line sizing. |
Performance and evaluation of hydraulic analysis and pressures
of line sizes. To evaluate quality of flows throughout the system.
Coordination with the Mississippi State Department of Health
to insure Minimum Design Standards were met. Address existing
supply and potential for expansion. Hydraulic Analysis, additionally,
addressed fire demand in accordance with Mississippi State Rating
Bureau. A cost analysis was performed of all items. |
City of Lumberton
P. O. Box 211
Lumberton, MS 39455
601-796-7000 |
Pearl River Community College
Water Improvements including an elevated tank, pumping station
and line sizing along with fire flows and domestic flows. |
Performance and evaluation of hydraulic analysis and pressures
of line sizes. To evaluate quality of flows throughout the system.
Coordination with the Mississippi State Department of Health
to insure Minimum Design Standards were met. Address existing
supply and potential for expansion. Hydraulic Analysis, additionally,
addressed fire demand in accordance with Mississippi State Rating
Bureau. A cost analysis was performed of all items. |
Pearl River Community College
Station A, Box 5090
Poplarville, MS 39470
601-795-6801 |
North Lumberton Utility Association
Water Improvements to include an elevated tank, water well
and domestic lines |
Performance and evaluation of Hydraulic Analysis, investigation
of existing storage and introduction of new elevated tank, investigation
of existing supply and introduction of new well, introduction
of new domestic lines. |
North Lumberton Utility Association
211 Main Street
Lumberton, MS 39455
601-796-4941 |
Hattiesburg Convention/Conference Center
Phase I and Phase II Environmental Assessment including wetlands survey |
Perform Phase I and Phase II assessments to determine any contamination
of soil or ground water. Of particular concern was for formaldehyde
leaking from an adjacent cemetery. Oversee the investigation
of a wetlands survey. |
Hattiesburg Convention/Conference Center
P. O. Box 1898
Hattiesburg, MS 39403
(601) 545-4640 |